Description
| MODEL SUPER MAX+ 40 KVA HIGH-FREQUENCY ONLINE UPS | |
| CAPACITY | 40KVA/ 40KW |
| DC VOLTAGE | Default= +192VDC (32 Battery) Adjustable= +240 VDC (40 Battery) |
| PHASE | 3 PHASE IN ~ 3 PHASE OUT |
| INPUT | |
| NOMINAL VOLTAGE | 3×400 VAC (3Ph+N) |
| ACCEPTABLE VOLTAGE RANGE | 190~520VAC (3 PHASE) @ 50% Load 305~478VAC (3 PHASE) @ 100% Load |
| FREQUENCY RANGE | 46~54 Hz or 56~64 Hz |
| POWER FACTOR | > 0.99 @ 100% Load |
| TOTAL HARMONIC DISTORTION THD(!) | <4% @ 100% R-Load, <5% @ 100% RCD Load at 230 VAC <6% @ 50% R-Load, <12% @ 50% RCD Load at 230 VAC |
| OUTPUT | |
| NOMINAL VOLTAGE | 3×360*/380/400/415 VAC (3Ph-N) |
| AC VOLTAGE REGULATION | + 1% (Battery Mode) |
| FREQUENCY RANGE | 46~54Hz or 56/64 Hz (Synchronized Range) 50Hz + 0.1Hz or 60Hz + 0.1 Hz (Battery Mode) |
| CURRENT CREST RATIO | 3:1 (Max) |
| HARMONIC DISTORTION | < 2% THD (Linear Load) : < 5% THD (Non-Linear Load) |
| OVERLOAD CAPABILITY | AC MODE: (100%-110% : 60Min) (110%-125%:10Min) (125%~150%:1Min) >150% : Immediately BATTERY MODE:(100%-110%:60Min) (110%-125%:10Min) (125%~150%:1Min) >150%: Immediately |
| TRANSFER TIME | |
| AC MODE TO BATTERY MODE | ZERO |
| INVERTER TO BYPASS | ZERO |
| WAVEFORM (BATTERY MODE) | PURE SINE WAVE |
| EFFICIENCY | AC MODE: 95.5% / ECO MODE: 98.5%, BATTERY MODE: 94.5% |
| BATTERY | |
| BATTERY TYPE | VRLA / LEAD-ACID TYPE |
| NUMBERS OF BATTERY | Default: 32 Nos. – Adjustable: 40 Nos. (Note: Double Bank in Series of (16~29) + (16~20) Battery with Center-Tapped Confirguration) |
| CHARGING CURRENT (MAX.) | 12A Maximum, adjustable = 1A to 12A, Factory Setting = 4A |
| CHARGING VOLTAGE | +/- 13.65V*N (N=16~20) |
| PHYSICAL | |
| DIMENTIONS PRODUCT (LxWxH) | 815x300x1000 (in mm) |
| NET WEIGHT PRODUCT (Kgs) | 61 Kgs. |
| ENVIRONMENT | |
| OPERATING HUMIDITY / TEMP. | <95% & Non-Condersing / 0.40°C |
| NOISE LEVEL / INGRESS PROTECTION (IP RATING) | Less Than 65dB @ 1 Meter / IP-20 |
| LCD INDICATION | UPS status, Load Percentage, Load Amperes on each phase, Output VA & Output Wattage per Phase, Battery Leval (Charging Ampere & Discharging Ampere), Input/Output Voltage (Phase to Neutral & Phase to Phase Voltage Information), Input/Output Frequency, Input Line Current per Phase, Input VA & Input Wattage Per Phase, Temperature Information and Data Log Events. |
| MANAGEMENT | |
| SMART RS-232 OR USB | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10 Linux & Mac |
| OPTIONAL SNMP | Power Management From SNMP Manager and Web Browser |









Reviews
There are no reviews yet.