Description
MODEL SUPER MAX+ 80 KVA With INBUILD ISO TRX HIGH FREQUENCY ONLINE UPS | |
CAPACITY | 80KVA/ 80KW With ISOLATION TRX |
PHASE | 3 PHASE IN ~ 3 PHASE OUT |
INPUT | |
NOMINAL VOLTAGE | 3×400 VAC (3Ph+N) |
ACCEPTABLE VOLTAGE RANGE | 190~520VAC (3 PHASE) @ 50% Load 305~478VAC (3 PHASE) @ 100% Load |
FREQUENCY RANGE | 46~54 Hz or 56~64 Hz |
POWER FACTOR | > 0.99 @ 100% Load |
OUTPUT | |
OUTPUT VOLTAGE | 3×360**/380/400/415 VAC (3Ph-N) |
AC VOLTAGE REGULATION BATTERY MODE | + 1% (Battery Mode) |
FREQUENCY RANGE | 46~54Hz or 56/64 Hz (Synchronized Range) 50Hz + 0.1Hz or 60Hz + 0.1 Hz (Battery Mode) |
CURRENT CREST RATIO | 2.6:1 (Max) |
HARMONIC DISTORTION (THDv) AT OUTPUT | < 2% THD (Linear Load) : < 10% THD (Non-Linear Load) |
OVERLOAD CAPABILITY | AC MODE: (100%-110% : 60Min) (110%-125%:10Min) (126%~150%:1Min) >150% for 400ms BATTERY MODE:(100%-110%:60Min) (110%-125%:10Min) (126%~150%:1Min) >150% for 400ms |
PARALLEL CAPACITY | Max upto 4-Units, with either Individual Battery bank OR Common battery bank |
TRANSFER TIME | |
AC MODE TO BATTERY MODE | ZERO |
INVERTER TO BYPASS | ZERO |
WAVEFORM (BATTERY MODE) | PURE SINE WAVE |
EFFICIENCY | AC MODE: 87.5% / ECO MODE: 93.5%, BATTERY MODE: 86.5% |
BATTERY | |
BATTERY TYPE | Depending on the capacity of external batteries |
NUMBERS OF BATTERY | Default: 32 Nos. – Adjustable: 40 Nos. |
CHARGING CURRENT (MAX.) | 2A~32A(Adjustable) |
CHARGING VOLTAGE | +/- 13.65V*N (N=16~20) |
ALARM | |
BATTERY MODE | Sounding every 4 seconds |
LOW BATTERY | Sounding every seconds |
OVERLOAD | Sounding Twice every seconds |
FAULT | Continuously sounding |
PHYSICAL | |
DIMENTIONS PRODUCT (DxWxH) | 790 x 720 x 1060 (in mm) |
NET WEIGHT PRODUCT (Kgs) | 475 Kgs. |
WARRANTY | 1 Year Product Warranty |
ENVIRONMENT | |
OPERATING HUMIDITY / TEMP. | <95% & Non-Condersing / 0.40°C |
NOISE LEVEL / INGRESS PROTECTION (IP RATING) | Less Than 75dB @ 1 Meter / IP-20 |
LCD INDICATION | UPS status, Load percentages & amperes on each phase at output, Output VA & Wattage in each phase. Battery level(Charging ampere & discharging ampere), Input/Output voltage (Phase to Neutral & phase to phase information), Input Line Current per phase, Input VA/Wattage/PF per phase, Temprature information, Data Log events(max 500 events) and Fault conditions. |
MANAGEMENT | |
SMART RS-232 OR USB | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10 Linux & Mac |
OPTIONAL SNMP | Power Management From SNMP Manager and Web Browser |
Reviews
There are no reviews yet.