HF SUPERMAX+ 60KVA, 3PH:3PH, ±240V(40-Battery System), DUAL INPUT, 5 INCH LCD TOUCH PANEL DISPLAY

KEY FEATURES

  • True double-conversion
  • DSP technolozy guarantees high performance
  • Output power factor 1
  • Active power factor correction in all phases at input
  • 50Hz/60Hz frequency converter mode
  • ECO mode operation for energy saving (ECO)
  • Emergency power off function (EPO)
  • Generator Compatible
  • SNMP+USB+RS-232 multiple communications
  • 3-stage extendable charging design for optimized battery performance
  • Adjustable battery numbers 32-40 battery
  • Parallel can be done with either individual battery bank on each UPS, or with Common Battery Bank
  • Waveform (Battery Mode) : Pure Sine Wave
WEIGHT 107kg
DIMENSIONS (L W H) 81.5x30x100

 

 

Enquiry

Description

 MODEL SUPER MAX+ 60 KVA HIGH FREQUENCY ONLINE UPS
 CAPACITY  60KVA/ 60KW
 PHASE  3 PHASE IN ~ 3 PHASE OUT

 

 INPUT
 NOMINAL VOLTAGE  3×400 VAC (3Ph+N)
 ACCEPTABLE VOLTAGE RANGE  190~520VAC (3 PHASE) @ 50% Load
 305~478VAC (3 PHASE) @ 100% Load
 FREQUENCY RANGE  46~54 Hz or 56~64 Hz
 POWER FACTOR  > 0.99 @ 100% Load
 HARMONIC DISTORTION (THDi)  <4% at full Linear Load

 

 OUTPUT
 OUTPUT VOLTAGE  3×360**/380/400/415 VAC (3Ph-N)
 AC VOLTAGE REGULATION BATTERY MODE  + 1% (Battery Mode)
 FREQUENCY RANGE  46~54Hz or 56/64 Hz (Synchronized Range)
 50Hz + 0.1Hz or 60Hz + 0.1 Hz (Battery Mode) 
 CURRENT CREST RATIO  3:1 (Max)
 HARMONIC DISTORTION (THDv) AT OUTPUT  < 2% THD (Linear Load) : < 5% THD (Non-Linear Load)
 OVERLOAD CAPABILITY  AC MODE: (100%-110% : 60Min) (110%-125%:10Min) (126%~150%:1Min) >150% for 400ms
 BATTERY MODE:(100%-110%:60Min) (110%-125%:10Min) (126%~150%:1Min) >150% for 400ms

 

 TRANSFER TIME
 AC MODE TO BATTERY MODE  ZERO
 INVERTER TO BYPASS  ZERO
 WAVEFORM (BATTERY MODE)  PURE SINE WAVE
 EFFICIENCY  AC MODE: 95.5% / ECO MODE: 98.5%, BATTERY MODE: 94.5%

 

 BATTERY
 BATTERY TYPE  SMF (VRLA) / LEAD-ACID BATTERIES
 NUMBERS OF BATTERY  Default: 32 Nos. – Adjustable: 40 Nos.
 (Note: Double Bank in Series of (16~29) + (16~20) Battery with Center-Tapped Confirguration)
 CHARGING CURRENT (MAX.) 2A~18A(Adjustable)
 CHARGING VOLTAGE  +/- 13.65V*N (N=16~20)

 

 ALARM
 BATTERY MODE  Sounding every 4 seconds
 LOW BATTERY  Sounding every seconds
 OVERLOAD  Sounding twice every seconds
FAULT  Continuously sounding

 

 PHYSICAL
 DIMENTIONS PRODUCT (DxWxH)  815 x 300 x 1000 (in mm)
 NET WEIGHT PRODUCT (Kgs)  74 Kgs.
 WARRANTY  1 Year Product Warranty

 

 ENVIRONMENT
 OPERATING HUMIDITY / TEMP.  <95% & Non-Condersing / 0.40°C
 NOISE LEVEL / INGRESS PROTECTION (IP RATING)  Less Than 70dB @ 1 Meter
 LCD INDICATION PANEL(5-INCH TOUCH DISPLAY)  UPS status, Load percentages & amperes on each phase at output, Output VA & Wattage in each phase. Battery level(Charging ampere & discharging ampere), Input/Output voltage (Phase to Neutral & phase to phase information), Input Line Current per phase, Input VA/Wattage/PF per phase, Temprature information, Data Log events(max 500 events) and Fault conditions.

 

 MANAGEMENT 
 SMART RS-232 OR USB   Supports Windows® 2000/2003/XP/Vista/2008/7/8/10 Linux & Mac
 OPTIONAL SNMP  Power Management From SNMP Manager and Web Browser

Reviews

There are no reviews yet.

Be the first to review “HF SUPERMAX+ 60KVA, 3PH:3PH, ±240V(40-Battery System), DUAL INPUT, 5 INCH LCD TOUCH PANEL DISPLAY”

Your email address will not be published. Required fields are marked *